ERCOT·WATCH Search ercot.com  ⌕
SCR #752 · Revision Request

SCR752  Nodal: Allow QSEs to Enter Outages for All Assets

Withdrawn sponsor The Transition Plan Task Force (TPTF) posted 2008-11-04 ercot.com
Reason1. The timeline to enter planned and unplanned Outages is critical. Coordination and communication is key to performing any Outage activity. If QSEs are required to coordinate with ERCOT Staff, within their own organizations and with Transmission Service Providers (TSPs), this could introduce an extra layer of complexity. As the owner, QSEs should be allowed to enter and be responsible for all updates for all of their assets. 2. The PUCT-approved Standard Generation Interconnection Agreement currently has no provision for the TSP to enter Outages for Transmission Elements operated by the QSE. This would have to be developed and a service level agreement put in place and would potentially require changes to the PUCT Rules. 3. There is currently no automatic transfer of Outage information between the QSE and TSP. To successfully have information flow, technology would be needed to allow the two or more entities to exchange data, and on an almost instantaneous basis. In some cases, the QSE may interact with several TSPs, and this would add to the complexity. There is no standard format in place for this system interface, so it would require development from the ground up. 4. As a QSE, the Lower Colorado River Authority (LCRA) performs studies assuming the Outage will be approved; however, when we receive updates to the contrary from ERCOT, we have to re-run our studies and often resubmit data. Adding third parties to this process will cause time delays and the potential for additional errors. With the tighter nodal timelines, this will negatively impact the market. 5. Accountability should lie with Entity responsible for the asset information updates.
Created2008-12-11
Sections Affected
Not applicable.
Summary
The ABB security software needs to accommodate a Qualified Scheduling Entity (QSE) security role that allows the QSE to enter Outage information for all of its Transmission Elements. To enter Outage information for Transmission Elements, the current ABB software would allow the QSE to view all transmission planning information. This is too broad and violates rules already in place.
Action Log 2 milestones
Documents 10
NameTypePostedClassification
752SCR-01 Allow QSEs to Enter Outages for all Assets 110408 doc Nov 4 '08 Revision Request
752SCR-03 TPTF Voting Ballot 102708 xls Nov 4 '08 Revision Request Ballot
752SCR-04 OWG Comments 120508 doc Dec 5 '08 Revision Request Comments
752SCR-05 ROS Action Report 121108 doc Dec 15 '08 Committee Report
752SCR-06 ERCOT Comments 121708 doc Dec 17 '08 Revision Request Comments
752SCR-07 ERCOT Comments 010909 doc Jan 9 '09 Revision Request Comments
752SCR-08 Calpine Comments 010909 doc Jan 9 '09 Revision Request Comments
752SCR-09 Request for Withdrawal 011509 doc Jan 15 '09 Committee Report
752SCR-10 TPTF Voting Ballot 011509 xls Feb 5 '09 Revision Request Ballot
752SCR-11 TPTF Voting Ballot 011509 xls Feb 5 '09 Revision Request Ballot
Meetings That Took It Up 4
DateMeetingCommitteeStatus
Jan 22 '09 PRS Meeting PRS Concluded
Jan 12 '09 TPTF Meeting TPTF Concluded
Dec 11 '08 ROS Meeting ROS Concluded
Nov 19 '08 OWG Meeting OWG Concluded